SPECIFICATIONS: Hi-Temp Air Amplifier
Performance Data
| Diameter | Model No. | Material | Throat Diameter | Amplification Ratio |
| 1¼" | SAM114HS | 316 Stainless - 700°F (371°C) | 1.01" (26 mm) | 16:1 |
| 2½" | SAM212HS | 316 Stainless - 700°F (371°C) | 2.03" (52 mm) | 25:1 |
How to Determine Air Consumption & Total Output Flow for any Adjustable Air Amplifier?
Total Airflow:
From the performance graphs (below), determine the total output flow for the Hi-Temp Adjustable Air Amplifier at any pressure.
Air Consumption:
(Tested with factory pre-set .002" Gap). See chart below for quick reference OR divide Total Output Flow by Amplification Ratio, using performance graphs below.
| Model SAM114HS (1-1/4") |
Model SAM212HS (2-1/2") |
|||
| PRESSURE SUPPLY | SCFM | SLPM | SCFM | SLPM |
| 20 PSIG (1.4 Bar) | 4.5 | 127 | 12.0 | 340 |
| 40 PSIG (2.8 Bar) | 7.0 | 198 | 19.5 | 552 |
| 60 PSIG (4.1 Bar) | 10.0 | 283 | 24.5 | 693 |
| 80 PSIG (5.5 Bar) | 13.0 | 367 | 29.0 | 821 |
| 100 PSIG (6.4 Bar) | 14.5 | 410 | 35.0 | 991 |
| 120 PSIG (8.4 Bar) | 17.0 | 481 | 42.0 | 1189 |
1-1/4" Adjustable Air Amplifier - Performance Graphs.
|
(120 KB) - Click to Enlarge Image |
(130 KB) - Click to Enlarge Image |
(130 KB) - Click to Enlarge Image |
(132 KB) - Click to Enlarge Image |
Adjustable Air Amplifier: DUCTING
Both the vacuum intake (inlet) and discharge ends can be ducted for fume conveying and light material applications. It is important that care is taken to avoid restrictions that could cause suction resistance or back pressure that will reduce the performance levels.
Adjustable Air Amplifier Air Flow Pattern

| MODEL NUMBER | A | B | C | D |
| SAM114A, SAM114S, SAM114HS | 2" (51mm) | 3" (76mm) | 4.8" (122mm) | 6.3" (160mm) |